Home › Equipment › Buying a commercial reach-in refrigerator in Georgia
Buying a commercial reach-in refrigerator in Georgia
- Pick what you need and give your kitchen's ZIP code.
- Each service goes to the number of local companies you choose, from one to five. We check licenses where the law requires one and email you their names.
- You talk with them and decide. You hire and pay the company directly.
Facts checked 2026-11-15.
A reach-in is the upright cabinet that holds cold food within arm's length of the line. A Georgia buyer picks the number of sections, the door style and whether the unit is a refrigerator, a freezer or a dual-temperature cabinet.
Kinds, sizes and fuel
Traulsen lists one, two and three section units and pass-thru units, with solid or glass doors. Hoshizaki lists one, two or three sections with full or half doors, in refrigerator, freezer and dual-temp versions, plus undercounter units.
Spec pages give the numbers to compare. A Beverage-Air two-door page lists R290 refrigerant, ENERGY STAR certification and a seven-year warranty on parts, labor and compressor, though the page also shows a one-door spec row, so confirm the exact model. A True one-door glass unit lists 115 volts and 2.2 amps, with NSF/ANSI 7 and cUL marks.
Makers of reach-in refrigerators include True, Beverage-Air, Hoshizaki and Traulsen.
What Georgia checks
Georgia's Chapter 511-6-1 was updated in February 2025 for the 2022 FDA Food Code. Under Rule .05 a cabinet has to be commercial grade, and certification by an ANSI-accredited program is deemed to satisfy the design rules. For reach-ins that standard is NSF/ANSI 7, covering commercial refrigerators and storage freezers, and UL's guide lists UL 471 for the electrical side.
Food that needs temperature control is held at 41 degrees F or below, or at 135 degrees F or above, in the 2022 Food Code's section 3-501.16. The same Food Code says cold-holding units for such food need a built-in temperature device in the warmest part of the unit, so look for a thermometer you can read. Capacity counts too, since the equipment chapter wants enough cooling to hold the temperatures.
A new or extensively remodeled restaurant sends plans to the county Environmental Health office, with fixed equipment listed by type and model. The opening a restaurant guide walks through where that review fits.
No hood requirement turned up for refrigeration in the sources read.
Fulton County's Environmental Health brochure adds a few practical points. A food service permit is the first of several steps, and the business license, any liquor license and zoning approval are separate. Permits do not transfer between people or locations, so a restaurant bought with its cabinets still needs its own permit. Check too whether the site is on public sewer or an on-site system, since that affects the dish and prep areas where cabinets often sit.
Get prices for this item. One request, and you pick how many sellers quote it.
Get quotesEfficiency and rebates
Two layers of energy rules apply. Federal rule 10 CFR 431.66 sets maximum daily kilowatt-hours for self-contained commercial refrigerators and freezers with solid or transparent doors, based on volume or display area, and the current limits apply to units made from March 27, 2017. The rule excludes salad bars, buffet tables and chef bases.
ENERGY STAR then certifies solid, transparent and mixed door units to Version 4.0 daily kWh limits. Prep tables, chef bases, open-air units and remote condensing units are out.
Georgia Power's rebate page, read in November 2026, shows hood and dishwasher items and no reach-in refrigerator. The ENERGY STAR Rebate Finder is the place to check your zip code, along with your utility.
What to ask a seller
- How many doors and sections does it have, and how many cubic feet inside?
- What are the voltage, amperage, plug type and refrigerant?
- Which marks does the exact model carry: NSF/ANSI 7, an electrical listing and ENERGY STAR?
- How long is the compressor warranty? Traulsen lists six years on parts and labor and seven on the compressor, and Beverage-Air lists seven.
- What rear and side clearances does the spec sheet require?
- Does it have a built-in thermometer you can see?
Submitting once reaches the local equipment sellers you select, between one and five.
Other kitchen equipment
Questions
What is the difference between a reach-in refrigerator and a walk-in?
A reach-in refrigerator is an upright cabinet, and a walk-in is a room-sized insulated box built from panels. Reach-ins come in one to three sections.
How cold must a commercial refrigerator hold food in Georgia?
A commercial refrigerator holds food that needs temperature control at 41 degrees F or below, under the 2022 Food Code section Georgia adopted. A readable thermometer helps you prove it.
Is there an ENERGY STAR reach-in refrigerator?
An ENERGY STAR reach-in refrigerator is certified for solid, transparent and mixed door units. Prep tables and chef bases are not eligible.
Does a reach-in need to meet a federal energy rule?
A reach-in with solid or transparent doors falls under the federal daily energy limits in 10 CFR 431.66. The maker's spec sheet will show the model's rating.
Sources
- Georgia DPH food service page
- Georgia Rule 511-6-1-.05, equipment
- Georgia Rule 511-6-1-.02, plan review
- FDA Food Code 2022 full text
- NSF certified food equipment listings, standard 7
- UL, Commercial Cooking Marking and Application Guide
- ENERGY STAR, commercial refrigerators and freezers
- ENERGY STAR Rebate Finder
- 10 CFR 431.66, commercial refrigerators and freezers
- Fulton County, starting a food service business
- Georgia Power business rebates
- Beverage-Air two-door reach-in
- Traulsen G Series
- Hoshizaki refrigeration